Edward Joseph & Sons

Edward Joseph & Sons My name is Eddie Quevedo and I am the principal owner of Edward Joseph & Sons. I am a local friend

Out with the old in with the new!!Replacement of old rewirable fuse board with new 18th Edition compliant consumer unit....
13/01/2022

Out with the old in with the new!!

Replacement of old rewirable fuse board with new 18th Edition compliant consumer unit.

Contact us for any Electrical or Gas Heating, Boiler repairs/installations

www.ejsons.com
[email protected]

We've recently completed a new wet central heating system designed installed tested and commissioned by Edward Joseph & ...
18/07/2021

We've recently completed a new wet central heating system designed installed tested and commissioned by Edward Joseph & Sons.

Our client wanted to replace the existing warm air system and update the property with a new modern wet central heating system which required a new boiler and copper piping connecting to new radiators. Each radiator is controlled locally via a TRV's.

The new boiler also provides instaneous hot water at all the hot tap outlets making the open vented hot water storage cylinder redundant from service. The property therefore benefits from additional storage space due to the removal of the open vented hot water cylinder, cold water tank and warm air heater.

Our client also benefits from a 10 year parts and labour warranty supported by the boiler manufacturer.

As well as new installations we also undertake repairs and servicing to heating systems.

Please get in touch or visit our website www.ejson.com for more information.

edward_joseph_sonsRecently completed installation of a new renewable energy efficient Air Source Heat Pump system. The c...
30/03/2021

edward_joseph_sons
Recently completed installation of a new renewable energy efficient Air Source Heat Pump system. The client built a new house from the ground up and decided they wanted a sustainable energy efficient system. The ASHP provides hot water and heating to a new wet underfloor heating system and traditional column radiators controlled by wireless thermostats. All installed, tested and commissioned by

Garden Furniture Restoration today for client in London.My son did all the hard work and told me he actually enjoyed the...
29/05/2019

Garden Furniture Restoration today for client in London.
My son did all the hard work and told me he actually enjoyed the sanding.

Reversed a set of double Doors which included removal of casement frame for the Pilots hub Café which is based at Redhil...
04/05/2019

Reversed a set of double Doors which included removal of casement frame for the Pilots hub Café which is based at Redhill Aerodrome.
Its a really nice spot to grab a coffee and bite to Eat whist watching the light aircraft. .
If you get a chance to visit I highly recommend the homemade chocolate brownies.

New Xpelair Extractor Ventilation Fan c/w overrun timer, supplied, installed and tested into new toilet. .External wall ...
24/04/2019

New Xpelair Extractor Ventilation Fan c/w overrun timer, supplied, installed and tested into new toilet. .

External wall core drilled to accommodate new fan, grille and interconnecting circular duct sleeve.

Fan switch positioned outside of toilet above door for safe isolation.

Floor tiling completed - it's actually a lot lighter but camera doesn't seem to translate.Next to fix shower, WC, WHB an...
03/04/2019

Floor tiling completed - it's actually a lot lighter but camera doesn't seem to translate.
Next to fix shower, WC, WHB and screen then finished.
@ London, United Kingdom

01/04/2019

Grinding curve on tile for shower base. It's noisy and messy but the end result is worth it.

Floor tiling completed on a new bathroom construction.  Lots of angle cuts and curves to scribe and cut which is always ...
01/04/2019

Floor tiling completed on a new bathroom construction. Lots of angle cuts and curves to scribe and cut which is always challenging but requires lots of patience. Overall very happy.

Emergency 'Call-out' to investigate faulty electric shower.  Upon investigation identified poor terminations at switched...
19/03/2019

Emergency 'Call-out' to investigate faulty electric shower. Upon investigation identified poor terminations at switched spur. Replaced spur and re-terminated with good practice. Also a design check was carried out on the cable size for its load and distance from consumer unit to the shower.
You can see where the terminal has melted due to arcing.
This client acted appropriately by contacting a professional electrician.
*if in doubt call a professional out*

Shower all tiled - bath wall and WHB backsplash left to do on Monday .
16/03/2019

Shower all tiled - bath wall and WHB backsplash left to do on Monday .

16/03/2019

It seems tedious but the end result is worth it IMHO